ATLAS PRO | OIL CALIBRATION TEST

From the home screen, tap the Menu button at the bottom center. This will take you to the Menu buttons. By tapping the SETTINGS button this will show you the 5 settings buttons available. 

Tap the MACHINE SETTINGS button and this will take you to the screen that allows you to test various settings. Tap the PUMP CALIBRATION button, this will take you to the screen where you can test either the oil pump or the cleaner pump. By tapping the OIL PUMP button, the screen will show the microliters, pump speed and volume.

Before performing your oil calibration test, you will need to purge the line by removing the oil tip assembly from the oil head and place it in the container used for your oil waste. By tapping either the Tank A or Tank B button, the oil head will begin to move back and forth, and the tip will begin dispensing conditioner until the 400 boards test has been completed. Once the first test has been run in your waste container, you can now run the test in your clean graduated cylinder for verification. Do this more than once to verify the output, thoroughly cleaning the cylinder after each test.

If an adjustment is needed, go to the PUMP SPEED line. You can adjust the motor speed up or down by using the left and right arrows for single increments. By tapping directly on the number, it will pop up a numerical keypad that you can directly input a specific motor speed. Keep in mind, that if an adjustment is made to the speed of the pump, it will affect both Tank A and Tank B. 

Was this article helpful?

Can’t find what you’re looking for?

Our award-winning customer support team is here for you.


24/7 TECH SUPPORT
Free award-winning tech support:
US Toll-Free: (800) 280 2695
International: +1 863 734 0200