REASON
- The machine is approaching the lane but the time limit for this operation has been reached. The current timeout for this operation is 10 seconds.
- The machine is moving on the lane and the LDS distance is greater than 4 feet and the OLS error has been triggered.
ERROR HAS BEEN TRIGGERED BUT THE MACHINE MOVING CORRECTLY
- OLS is not properly adjusted
- Yellow/Orange wire at the terminal block is broke
- OLS sensor is bad
- LDS shaft is in a bind
- OLS is not wired to input 6
- Input 6 on the input board has failed