ATLAS PRO | OLS FORWARD

REASON

  • The machine is approaching the lane but the time limit for this operation has been reached. The current timeout for this operation is 10 seconds. 
  • The machine is moving on the lane and the LDS distance is greater than 4 feet and the OLS error has been triggered.

ERROR HAS BEEN TRIGGERED BUT THE MACHINE MOVING CORRECTLY

  • OLS is not properly adjusted 
  • Yellow/Orange wire at the terminal block is broke
  • OLS sensor is bad
  • LDS shaft is in a bind
  • OLS is not wired to input 6 
  • Input 6 on the input board has failed

 

 

 

 