The brush lift motor runs, but the down switch failed to operate.
Brush down switch faulty
P Brush up switch faulty
Possible broken wire
Loose connection in either the yellow 24Vdc wire or the Violet/Yellow wire that connects to input 18
Loose set screw on motor cam
Brush lift motor does not run.
Fuse is blown (3.2A) HOW TO CHECK
PARROT
Bad connection to motor
White/Black wire broken from relay output
Output CR-3 failed
Motor has failed
Possible Causes The brush lift motor runs, but the down switch failed to operate. Brush down switch faulty P Brush up switch faulty Possible broken wire
Loose connection in either the yellow 24Vdc wire or the Violet/Yellow wire that connects to input 18 Loose set screw on motor cam