ATLAS WALKER | SQUEEGEE DOWN

Error Property

Value

Fatal

Yes

Machine

AW, AT

REASON

  •       The machine is applying cleaner and the LDS distance is greater than 1 foot and the  squeegee up switch signal is activated. 

 

Problem

Possible Causes

The squeegee motor runs but the down switch failed to operate to send a signal. 

  •       Check and inspect the switch
  •       Loose connection at the yellow 24Vdc wire
  •       Loose set screw on motor cam
  •       Broken black wire or loose connection to input 30
  •       The squeegee up switch is engaged

The squeegee motor does not run.

  •       Fuse is blown (3.2A)  HOW TO CHECK
  •       Bad fuse holder
  •       Squeegee linkage is in a bind
  •       Relay CR-2 has failed
  •       Bad connection to the motor 
  •       Broken Blue/white wire 
  •       Motor has failed