ATLAS | BUFFER BRUSH DOWN

Error Property

Value

Fatal

Yes

Machine

AW, AT

REASON         

  •      Machine is oiling forward and the LDS distance is greater than 3 feet and the upper switch of the brush is engaged. 
  •      Machine is oiling in reverse and the LDS distance is less than the pattern reverse drop brush distance and the upper switch of the brush is engaged. 

 

Problem

Possible Causes

The brush lift motor runs, but the down switch failed to operate.

  •      Brush down switch faulty
  •      Brush up switch faulty
  •      Possible broken wire
  •      Loose connection in either the yellow 24Vdc wire or the Violet/Yellow wire that connects to input 18
  •      Loose set screw on motor cam

Brush lift motor does not run.

  •      Fuse is blown (3.2A)  HOW TO CHECK
  •      Fuse holder is bad
  •      Bad connection to motor 
  •      White/Black wire broken from relay output
  •      Output CR-3 failed 
  •      Motor has failed