ATLAS WALKER | SQUEEGEE UP

Error Property

Value

Fatal

Yes

Machine

AW, AT

REASON

  •      The machine is resetting the squeegee to the up position and the squeegee up switch signal has not been activated within 2 seconds. 

 

Problem

Possible Causes

The squeegee motor runs but the squeegee up switch failed to send a signal. 

  •      Check and inspect the switch
  •      Loose connection at the yellow 24Vdc wire
  •      Loose set screw on motor cam
  •      Possible broken Yellow/Green wire or loose connection to input 20
  •      The squeegee down switch is engaged
  •      Input 20 on input board has failed

The squeegee motor does not run.

  •      Fuse is blown (3.2A)  HOW TO CHECK
  •      Bad fuse holder
  •      Squeegee linkage is in a bind
  •      Relay CR-2 has failed
  •      Bad connection to the motor 
  •      Defective motor

 