ATLAS | BUFFER BRUSH UP

Error Property

Value

Fatal

Yes

Machine

AW, AT

REASON

  •       Machine is resetting the buffer brush position and more than 2 seconds have elapsed without having a signal from the brush up switch. 

 

Problem

Possible Causes

The brush lift motor runs, but the up switch failed to operate.

  •      Buffer up switch faulty
  •      Brush down switch faulty
  •      Possible broken wire
  •      Loose connection in either the yellow 24 Vdc wire or the Green/White wire that connects to input 22
  •      Loose set screw on motor cam

Brush lift motor does not run.

  •      Fuse is blown (3.2A)  HOW TO CHECK
  •      Fuse holder is bad
  •      Bad connection to motor
  •      White/Black wire broken from relay output
  •      Output CR-3 failed
  •      Motor has failed