ATLAS | SQUEEGEE UP

REASON

  • The machine is resetting the squeegee to the up position and the squeegee up switch signal has not been activated within 2 seconds.      

THE SQUEEGEE MOTOR RUNS BUT THE SQUEEGEE UP SWITCH FAILED TO SEND A SIGNAL

  • Check and inspect the switch
  • Loose connection at the yellow 24Vdc wire
  • Loose set screw on motor cam
  • Possible broken Yellow/Green wire
  • Loose connection to input 20
  • The squeegee down switch is engaged
  • Input 20 on input board has failed

THE SQUEEGEE MOTOR DOES NOT RUN

  • Fuse is blown (3.25A)
  • Bad fuse holder
  • Squeegee linkage is in a bind
  • Relay CR-2 has failed
  • Bad connection to the motor
  • Defective motor

 

 

Was this article helpful?

Can’t find what you’re looking for?

Our award-winning customer support team is here for you.


24/7 TECH SUPPORT
Free award-winning tech support:
US Toll-Free: (800) 280 2695
International: +1 863 734 0200