ATLAS | CONTROL BOARD CONNECTION

Error Property

Value

Fatal

Yes

Machine

AW, AT

REASON

  •      Main controller is trying to establish communication with control board for more than 5 seconds and there is no response from control board. 

 

Problem

Possible Causes

Any action on machine is triggering this error. 

  •      Blown fuse (1A)  HOW TO CHECK
  •      Fuse holder defective
  •      Control board not physically connected 
  •      Bad RJ45 cable that connects controller with control board 
  •      The control board has no power
  •      Control board connected to the wrong ethernet port of the controller